Product Name
Gap Junction Protein Beta 6 (GJb6), ELISA Kit
Full Product Name
Gap Junction Protein Beta 6 (GJb6) ELISA Kit
Product Synonym Names
HED; DFNA3; CX30; ED2; EDH; Ectodermal Dysplasia 2,Hidrotic; Connexin 30
Product Gene Name
GJb6 elisa kit
[Similar Products]
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Sample Manual Insert
Download Sample PDF Manual View Sample PDF Manual
Request for Current Manual Insert
Request Current Manual
Specificity
This assay has high sensitivity and excellent specificity for detection of Gap Junction Protein Beta 6 (GJb6).
No significant cross-reactivity or interference between Gap Junction Protein Beta 6 (GJb6) and analogues was observed.
Assay Type
Double-antibody Sandwich
Samples
Tissue homogenates, Cell lysates and Other Biological Fluids
Detection Range
0.312-20ng/mL
Application
Enzyme-linked immunosorbent assay for Antigen Detection.
Intra-assay Precision (Precision within an assay)
3 samples with low, middle and high level Gap Junction Protein Beta 6 (GJb6) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays)
3 samples with low, middle and high level Gap Junction Protein Beta 6 (GJb6) were tested on 3 different plates, 8 replicates in each plate.
Preparation and Storage
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
ISO Certification
Manufactured in an ISO 9001:2008 and ISO 13485:2003 Certified Laboratory.
Supply Chain Verification
Manufactured in a lab with traceable raw materials. Bulk orders can typically be prepared to the customera??s specifications, please inquire.
Product Note
Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of GJb6 elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms for GJb6 purchase
MBS2025114 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Gap Junction Protein Beta 6 (GJb6) ELISA Kit target analytes in
biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing GJb6. The ELISA analytical biochemical technique of the MBS2025114 kit is based on GJb6 antibody-GJb6 antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect GJb6 antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, GJb6. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Related Product Information for
GJb6 elisa kit
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Gap Junction Protein Beta 6 (GJb6). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Gap Junction Protein Beta 6 (GJb6). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Gap Junction Protein Beta 6 (GJb6), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Gap Junction Protein Beta 6 (GJb6) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
Product Categories/Family for GJb6 elisa kit
Signal transduction
Typical Testing Data/Standard Curve (for reference only) of GJb6 elisa kit
NCBI/Uniprot data below describe general gene information for GJb6. It may not necessarily be applicable to this product.
NCBI Accession #
AAH38934.1
[Other Products]
UniProt Secondary Accession #
Q5Q1H9; Q5Q1I0; Q5Q1I1; Q5T5U0; Q8IUP0; B3KQN2[Other Products]
UniProt Related Accession #
O95452[Other Products]
Molecular Weight
30,387 Da
NCBI Official Full Name
Gap junction protein, beta 6, 30kDa
NCBI Official Synonym Full Names
gap junction protein, beta 6, 30kDa
NCBI Official Symbol
GJB6??[Similar Products]
NCBI Official Synonym Symbols
ED2; EDH; HED; CX30; HED2; DFNA3; ECTD2; DFNA3B; DFNB1B
??[Similar Products]
NCBI Protein Information
gap junction beta-6 protein
UniProt Protein Name
Gap junction beta-6 protein
UniProt Synonym Protein Names
Connexin-30; Cx30
Protein Family
Gap junction beta-6 protein
UniProt Gene Name
GJB6??[Similar Products]
UniProt Synonym Gene Names
Cx30??[Similar Products]
UniProt Entry Name
CXB6_HUMAN
NCBI Summary for GJb6
Gap junctions allow the transport of ions and metabolites between the cytoplasm of adjacent cells. They are formed by two hemichannels, made up of six connexin proteins assembled in groups. Each connexin protein has four transmembrane segments, two extracellular loops, a cytoplasmic loop formed between the two inner transmembrane segments, and the N- and C-terminus both being in the cytoplasm. The specificity of the gap junction is determined by which connexin proteins comprise the hemichannel. In the past, connexin protein names were based on their molecular weight, however the new nomenclature uses sequential numbers based on which form (alpha or beta) of the gap junction is present. This gene encodes one of the connexin proteins. Mutations in this gene have been found in some forms of deafness and in some families with hidrotic ectodermal dysplasia. [provided by RefSeq, Jul 2008]
UniProt Comments for GJb6
GJB6: One gap junction consists of a cluster of closely packed pairs of transmembrane channels, the connexons, through which materials of low MW diffuse from one cell to a neighboring cell. Belongs to the connexin family. Beta-type (group I) subfamily. A connexon is composed of a hexamer of connexins. Interacts with CNST
Protein type: Membrane protein, multi-pass
Chromosomal Location of Human Ortholog: 13q12
Cellular Component: connexon complex; apical plasma membrane; integral to membrane; cytosol
Biological Process: negative regulation of cell proliferation; sensory perception of sound; apoptosis; cell communication; response to lipopolysaccharide; ear morphogenesis; response to electrical stimulus; inner ear development; aging
Disease: Deafness, Autosomal Recessive 1a; Clouston Syndrome; Deafness, Autosomal Recessive 1b; Deafness, X-linked 2; Deafness, Autosomal Dominant 3b
Research Articles on GJb6
1. Mutations in GJB2, GJB6 and GJA1 are not a major cause of non-syndromic deafness in black Africans
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.
It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.